Aquatube AQT Series High Efficiency Low Water Volume  BOILER
S.P. THERMAL SYSTEMS INC.
Low Water Volume Boiler Specialist in Ontario, Canada
Group Simoneau Inc. manufactures a range of Low Water Volume "Steam Boilers", "Hot Water Boilers" and "Thermal Fluid" glycol Boilers. These boilers are designed by Thermodesign Inc.

The Aquatube AQT Series of Low Water Steam boilers are a Water Tube type boiler. These boilers  are approved by TSSA and are Operator Exempt in Ontario, Canada to a Maximum of 1500 BHP
Larger sizes are achievable with some staffing (see TSSA rules)

Units are Manufactured in sizes  from 100 to 600 BHP in 50 BHP increments,  as High and  Low pressure Steam.

These Aquatube units can be fired on Gas or # 2 Oil.
The Boilers come with Full Burner Modulation having a turndown available as Low as 8:1 using special burners

These Low Volume units are supplied with an integrated economizer, producing efficiencies as high as 85% with a feed water temperature of 180F, exceeding most other suppliers efficiency claims.

The Aquatube AQT Series, boilers come with a Wet Back design and double insulation on the side walls, reducing radiation losses and refractory replacement cost.


         FEATURES OF THE  AQUATUBE - AQT Series Low Water Volume BOILERS
                                   
AQT Series c/w TSSA, ASME, CSA, CRN approvals from Factory. ULC on burner included.   

Operator Exempt boilers in Ontario, Canada to a Maximum of 1500 BHP (2 x 600 + 1 x 300 BHP)

3 Gas Pass staggered tube design,  achieving maximum heat transfer. Efficiencies above 85% is achieved with built in  Economizer at Feed Water temperature of 180 F and at 200 psig

Fast response to Steam in less than 5 minutes from cold start.

Full Burner Modulation  4: 1 turndown. Higher available to 8:1 reducing Purge Loss

Generous Furnace  volume design producing Low NOx.  Meets Ontario regulations. 

Large heating surface, increasing  boiler life. Almost three times higher than competitors products

These Low Volume Boilers can operate on Gas or # 2 Oil. Combination fuels are also available

Very Low Electric consumption, saving  $8000 or more / year versus similar competitive boilers

All tubes can be replaced or repaired should a failure occur

Maximum design pressure 250 psig.  Maximum operating pressure 200 psig

Wet Back Design eliminating costly refractory repairs

Balanced Flow design eliminating potential Thermal shock failures

Larger Steam Space than competitors products,  providing Steam Quality of 99.5% saturated dry steam

All Parts are available from many "Local" Boiler Suppliers, reducing after market costs.

No Secondary circulating pump required. Unit supplied with natural  circulation,  reducing cost

Excellent control of Water Treatment due to true surface blowdown point  & good steam quality 

Service can be done by any contractor reducing  high service cost from manufacturer

Compare Operating and installation cost  on these AQT Series Boiler units, versus competitor units, before purchasing.  We are confident you will not find similar features and savings.

Request an Anticipated Performance Report based on your operating conditions,  for comparison against competitive products.

Warranties Offered:  - 20 Years  Thermal Shock ;  10 Years on Pressure Vessel, against workmanship


S.P. THERMAL SYSTEMS INC.
4504 Green Meadow Blvd.
Beamsville, Ontario, Canada, L0R 1B5
Ph. 905 563 8651 or Fax 905 563 6234
Cell: 416 876 0684
E-mail    spthermal@cogeco.ca
AQUATUBE  Boiler      Drawings   
Power Flame Burner
* Gas Fired
* Gas & Oil also        available.
AQUATUBE Boiler
Cad Drawings
Power Flame Burner
* Gas Fired
* Gas & Oil also        available.
Drawings shown are subject to change by the manufacturer. Please consult with us for the latest addition or changes.
Please also contact us for drawings of other types of boilers or sizes manufactured by Group Simoneau Inc.
Group Simoneau "Low  Water Volume" Boiler
Used Miura Boilers, Group Simoneau Boiler, Low Water Volume Boilers, Low Volume Boilers, Used Low Water Volume Boilers, Hurst Boiler, AQT Series Boilers, Aquatube Boiler, Water Treatment Consultants and supplier of Boiler Chemicals, Cooling Tower Chemicals, Water Treatment Equipment, Boiler auxiliaries such as Automatic Blowdown Controllers, Chemical Pumps, Softeners, Contact Water Meters, Blowdown Tanks, Feed Water Tanks, Deaerators,  Water Tube Boilers, Hot Water Boilers, Thermal Fluid Boilers, Lead lag Controls, A type boilers, O type Boilers, D type Boilers
NOTE: Save money on High Fuel Cost and take advantage of Incentive Grants available through Gas Companies
Use Mouse to LINK
Designed by
S.P. Thermal Systems Inc.
designed with Homestead
Low Volume Water Tube Steam Boilers Drawings
Complete Boiler and Water Treatment Training review summary, including Water Treatment testing procedures.
Click above Email us
Tell a friend about this page
Low Volume Water Tube Steam Boilers Drawings
TSSA Low Water Volume Approval Letter
We specialize in the Low Water Volume Boiler Market in Ontario. These boilers do not require Engineers, in Ontario Canada
Low Water Volume, Water Tube Boilers in Steam & Hot Water up to 600 BHP size
Aquatube Boiler
AQT Series
"A" Type Boilers Available
"D" Type Boilers available
"O" Type Boilers available
Other Types of Boilers
manufactured by
Group Simoneau